+86-18651128828

Phone line

Pelvic Long Fixator with Ball-Jointed Modules for Independent Screw Placement

  1. Pelvic Focus: Specifically designed for pelvic injuries.
  2. Ball-Jointed Modules: Offer flexibility.
  3. Independent Screw Placement: Allows for precision.
  4. Durable Construction: Long-lasting and reliable.
  5. Easy to Use: Convenient for medical professionals.
CODEPRODUCTIONDESCRIPTIONMATERIAL
ZG003Pelvic Long Fixator with Ball-Jointed Modules for Independent Screw PlacementWhole setAluminum

 

Key Features and Benefits of the Pelvic Long Fixator with Ball – Jointed Modules for Independent Screw Placement

Key Features

  • Ball – Jointed Modules for Enhanced Flexibility: The incorporation of ball – jointed modules is a standout feature. These modules allow for a high degree of movement and adjustment, enabling the fixator to adapt to the unique anatomical contours of the pelvis. In pelvic injury cases where the fracture patterns can be complex and vary from patient to patient, this flexibility is crucial. It means that the fixator can be positioned precisely to provide the necessary support exactly where it’s needed, regardless of the specific shape or angle of the pelvic bones.
  • Independent Screw Placement for Customization: The ability to place screws independently offers precise customization in treating pelvic injuries. Surgeons can carefully determine the optimal position and angle of each screw based on the individual fracture characteristics. For example, in a case with multiple fragmented bones, each screw can be placed to target specific bone segments, ensuring maximum stability and alignment. This level of precision is not easily achievable with traditional fixators and greatly enhances the effectiveness of the treatment.
  • High – Quality Materials for Durability: Constructed from high – quality materials, the pelvic long fixator is built to withstand the rigors of the body’s internal environment and the demands of the healing process. The materials are carefully selected to resist corrosion, wear, and tear, ensuring that the fixator remains reliable throughout the treatment period. This durability is essential as it reduces the risk of device failure, which could potentially lead to complications or the need for additional surgeries.
  • User – Friendly Design for Efficiency: The design of the fixator is intuitive and easy for medical professionals to use. Its components are engineered in a way that simplifies the surgical implantation process, saving valuable time and effort during surgeries. For instance, the ball – jointed modules and screw placement mechanisms are likely to be designed with ease of manipulation in mind, allowing surgeons to focus more on the patient’s condition and the accuracy of the procedure rather than struggling with a complicated device.

Benefits

  • Optimal Stability for Healing: By providing a stable and supportive framework for the pelvis, the fixator creates an ideal environment for proper bone healing. The precise screw placement and adaptable design work together to hold the pelvic bones in the correct alignment, minimizing any movement that could disrupt the healing process. This stability is key to ensuring that fractures heal as quickly and effectively as possible, reducing the risk of long – term complications such as misalignment or delayed healing.
  • Improved Treatment Outcomes: The combination of flexibility, customization, and stability offered by this fixator leads to improved treatment outcomes. Patients are more likely to experience a full recovery with better restoration of pelvic function. The ability to tailor the fixation to the specific injury means that each patient receives the most appropriate treatment, increasing the chances of a successful rehabilitation and a return to normal activities.
  • Versatility in Pelvic Injury Treatment: The unique features of the pelvic long fixator make it a versatile tool in treating a wide range of pelvic injuries. Whether it’s a simple fracture or a complex, multi – fragmented injury, the fixator can be adjusted and customized to meet the specific requirements of the case. This versatility allows medical professionals to rely on it as a go – to solution for various pelvic trauma scenarios, streamlining the treatment process and ensuring consistent quality of care.
  • Enhanced Patient Comfort: During the healing process, the fixator’s stable and well – fitted design helps to minimize discomfort for the patient. Unlike poorly fitting or rigid devices that could cause irritation or pain, this fixator’s adaptability ensures that it conforms to the body’s natural movements as much as possible. This not only improves the patient’s overall experience during recovery but also encourages better compliance with post – surgical care instructions

Indications for Pelvic Long Fixator with Ball – Jointed Modules for Independent Screw Placement

  • Complex Pelvic Fractures: In situations where the pelvic bones are broken into multiple fragments or have intricate fracture patterns, this fixator is highly indicated. The independent screw placement and ball – jointed modules come into play as they enable surgeons to precisely position screws to hold each fragment in the correct alignment. For example, in fractures caused by high – energy impacts like car accidents or falls from significant heights, where the pelvic ring may be severely disrupted with various bone segments out of place, this fixator can be customized to address the complexity and ensure stable fixation for proper healing.
  • Pelvic Instabilities: When the pelvis is unstable due to ligament damage, congenital deformities, or other factors that affect its structural integrity, the Pelvic Long Fixator with Ball – Jointed Modules for Independent Screw Placement is a valuable tool. It provides the necessary external support to restore stability. The ball – jointed design allows for adjustments to match the specific anatomical requirements of the patient, while the independent screw placement ensures that the fixation is tailored to the areas where stability needs to be enhanced. This helps in preventing further displacement of the pelvic bones and promotes the body’s natural healing process.
  • Severe Trauma Cases: In severe trauma scenarios, where precise fixation and accurate alignment of the pelvis are of utmost importance for a successful recovery, this fixator shines. It can be used in cases where immediate stabilization is required to prevent complications such as bleeding from damaged blood vessels around the pelvis or damage to internal organs due to the instability. The ability to customize the treatment based on the specific trauma-induced pelvic injury means that surgeons can quickly and effectively use this device to secure the pelvis, minimizing the risk of long – term functional impairments and facilitating a smoother healing journey.
  • Challenging Pelvic Injuries: Overall, for any pelvic injury that presents challenges in terms of achieving proper fixation, alignment, or stability due to its unique anatomical or pathological nature, this specialized fixator is indicated. It offers the flexibility and precision needed to handle these difficult cases, making it an essential device in the orthopedic surgeon’s toolkit for treating a wide variety of complex and challenging pelvic conditions

How Does The Pelvic Long Fixator with Ball – Jointed Modules for Independent Screw Placement Work


  1. Surgical Placement and Positioning
    • The first step in using the Pelvic Long Fixator is the surgical placement around the pelvis. Surgeons carefully position the fixator to ensure it is in the most optimal location to address the specific pelvic injury. The length of the fixator is designed to cover the necessary area of the pelvis, which is crucial for comprehensive support. The ball – jointed modules play a vital role during this initial positioning. Their flexibility allows the fixator to conform to the unique shape and contours of the patient’s pelvis. For example, in a patient with an irregularly shaped pelvis due to a congenital condition or previous injury, the ball – jointed modules can adjust to fit snugly around the pelvic bones.
  2. Independent Screw Placement for Precise Fixation
    • Once the fixator is in position, the independent screw placement feature comes into action. Surgeons use the appropriate surgical instruments to insert screws into the bone through the fixator. The ability to place screws independently is a key advantage. Each screw can be precisely positioned to target specific areas of the fractured or unstable pelvis. For instance, in a complex pelvic fracture with multiple fragments, the surgeon can angle and place each screw to hold individual bone fragments in the correct alignment. This precision helps to restore the normal anatomical structure of the pelvis as much as possible. The screws provide a secure connection between the fixator and the bone, ensuring that the fixator remains in place during the healing process.
  3. Balance of Movement and Stability via Ball – Joints
    • The ball – joints in the fixator provide a unique combination of movement and stability. While the screws firmly attach the fixator to the bone, the ball – joints allow for a certain degree of movement. This movement is carefully calibrated to mimic the natural range of motion of the pelvis to some extent. It is essential because it prevents the fixator from being too rigid and causing discomfort or interfering with the body’s normal physiological functions. At the same time, the ball – joints maintain the overall stability of the fixator – bone construct. They ensure that the fixator doesn’t shift out of position during normal body movements such as walking or sitting. This balance is crucial for promoting proper healing as it allows the pelvis to experience some natural stress, which can stimulate bone growth and remodeling, while still providing the necessary support to prevent further damage.
  4. Support during the Healing Process
    • As the body begins to heal, the Pelvic Long Fixator serves as a continuous support structure for the pelvis. It helps to keep the fractured or unstable parts of the pelvis in the correct alignment, allowing the bones to heal properly. The fixator’s stability reduces the risk of misalignment due to external forces or the patient’s own movements. It also provides a stable environment for the bone – healing process, which includes the formation of callus and the remodeling of bone tissue. By maintaining the proper position of the pelvic bones, the fixator helps to ensure that the healing occurs in a way that restores the normal function of the pelvis as much as possible.
  5. Removal after Healing
    • Once the healing process is complete, as determined by the medical team through various diagnostic methods such as X – rays or CT scans, the fixator can be removed. The removal process is a surgical procedure, usually less complex than the initial implantation. Surgeons carefully detach the fixator from the bone by removing the screws and then take out the fixator. After removal, the patient continues with rehabilitation to regain full strength and function of the pelvis. The use of this fixator throughout the healing process helps to optimize the chances of a successful recovery from complex pelvic fractures or instabilities.
 
 

Frequently Asked Questions

Q1: What is it made of?

A:
The Pelvic Long Fixator is typically constructed from medical - grade materials. These materials are carefully selected to ensure both durability and biocompatibility. Durability is crucial as the fixator needs to withstand the forces exerted during the healing process and normal body movements. Biocompatibility means that the body's immune system is less likely to react negatively to the fixator, reducing the risk of complications such as inflammation or rejection. Commonly used materials may include high - quality stainless steel or titanium alloys, which have excellent mechanical properties and are well - tolerated by the body

Q2: How do the ball - jointed modules work?

A:
The ball - jointed modules are a key component of the fixator's design. They provide flexibility and adaptability during the fixation process. The ball - joint structure allows for a range of movement similar to a ball - and - socket joint. This enables the fixator to conform to the unique shape of the patient's pelvis. For example, if the pelvic bones have an irregular contour due to a fracture or a congenital condition, the ball - jointed modules can adjust to ensure a proper fit. They also allow for some degree of movement during the healing process, which helps to mimic the natural motion of the pelvis and provides a more comfortable and effective fixation

Q3: Is it easy to use?

A:
The fixator is designed to be user - friendly for medical professionals. The components are engineered in a way that simplifies the surgical implantation and adjustment process. The ball - jointed modules and screw placement mechanisms are usually designed to be intuitive and easy to manipulate. However, like any medical device, it requires a certain level of skill and knowledge. The ease of use also depends on the experience and training of the medical staff using it.

Q4: Can the screws be placed independently?

A:
Yes, the independent screw placement is one of the major advantages of this fixator. This feature allows for customized fixation. Surgeons can carefully position each screw according to the specific requirements of the pelvic injury. In a complex fracture situation, for example, they can target individual bone fragments and adjust the angle and depth of each screw to achieve the best possible fixation and alignment of the pelvis.

Q5: Does it come in different sizes?

A:
It may be available in various sizes to fit different patients. The size range is designed to accommodate the anatomical differences in pelvic size and shape among individuals. This ensures that the fixator can provide effective support and fixation regardless of the patient's body dimensions. Medical staff can select the most appropriate size based on pre - operative assessments such as X - rays or CT scans that show the size and structure of the patient's pelvis.

Q6: How durable is it?

A:
The fixator is made from durable materials to withstand the demands of the healing process. As mentioned earlier, materials like stainless steel or titanium alloys are used for their strength and resistance to wear and tear. The fixator needs to maintain its integrity throughout the healing period, which can range from several weeks to months. During this time, it is subjected to the body's natural movements and the forces associated with bone healing, so its durability is essential to ensure successful treatment.

Q7: Can it be adjusted?

A:
Some adjustments may be possible with the ball - jointed modules. These adjustments can be made during the initial implantation to ensure a proper fit around the pelvis. Additionally, in some cases, minor adjustments might be considered during the healing process if necessary. However, any adjustments would be carefully evaluated and carried out by medical professionals to avoid disrupting the healing process or causing harm to the patient.

Q8: What procedures is it used in?

A:
This fixator is primarily used in complex pelvic fracture fixation surgeries. It is also indicated for cases of pelvic instability, such as when the pelvic bones are misaligned due to trauma, congenital deformities, or ligament damage. The device provides the necessary support and fixation to promote proper healing and restoration of pelvic function in these complex procedures.

Q9: How accurate is the screw placement?

A:
The independent placement of screws offers a high level of precision. Surgeons can use their anatomical knowledge and surgical skills to position each screw with great accuracy. This precision is crucial for achieving the best possible fixation and alignment of the pelvic bones. The ability to target specific areas of the pelvis, especially in complex fractures with multiple fragments, significantly improves the effectiveness of the treatment and the chances of a successful recovery.

Q10: Does it require special training to use?

A:
Some training may be beneficial for the proper application of the Pelvic Long Fixator. While the device is designed to be user - friendly, medical professionals need to understand its features, such as the ball - jointed modules and independent screw placement, to use it effectively. Training programs typically cover the surgical techniques for implantation, adjustment, and removal of the fixator, as well as the understanding of the biomechanics involved in pelvic fixation to ensure safe and successful treatment.

Related Articles

Request A Free Quote

Oh yeah! I have to mention their payment options and discount offers, which are awesome! Those payment methods are as flexible as moving water and can be chosen freely according to our cash flow situation. And the frequent discounts, like a timely rain, have been moisturizing our financial statements time and again, and have had a rocket-like positive impact on our profits! With ZMD, I feel relaxed and at ease when it comes to purchasing!

We'd like to work with you

Send us a message if you have any questions or request a quote. Our experts will give you a reply within 24 hours and help you select the right valve you want.

We have an exclusive service of medical products for you, please leave your details and we will contact you as soon as possible.