- Home
- About Us
- Products
- Trauma Internal Fixation System
- Spinal Internal Fixation System
- External Fixation
- Artificial Implants System
- Sports Medicine
- Power tools
- VSD System
- Instruments
- Blog
- Personnel Profile
- Contact Us
Phone line
1.Enhanced Structural Integrity: The increased thickness of 0.8mm and width of 2.0mm provide superior strength and stability compared to thinner options, ensuring reliable bone fixation.
2.Minimal Invasive Profile: While offering enhanced strength, the plate maintains a low profile, minimizing tissue disruption and accelerating patient recovery.
3.Versatility: The straight bridge design offers adaptability to various bone configurations, providing flexibility in surgical applications.
4.Precise Engineering: The combination of increased thickness and locking mechanism allows for precise bone alignment and stabilization.
5.Biocompatible Material: Crafted from high-grade titanium, the plate offers exceptional strength, biocompatibility, and resistance to corrosion.
Code | Product name | Size | Related Screwdriver |
5213.0803 | Straight Locking Plate 2.0mm | 6holes 35mm | 2.0mm |
5213.0804 | Straight Locking Plate 2.0mm | 8holes 47mm | 2.0mm |
5213.0805 | Straight Locking Plate 2.0mm | 12holes 71mm | 2.0mm |
5213.0806 | Straight Locking Plate 2.0mm | 16holes 95mm | 2.0mm |
Key Features and Benefits of the Straight Locking Plate 2.0mm
The Straight Locking Plate 2.0mm offers exceptional strength and stability for demanding orthopedic and maxillofacial procedures. Its increased dimensions provide robust support for larger bone segments and high-load-bearing areas. The locking mechanism ensures secure fixation, preventing implant migration. This combination of strength, stability, and low profile makes it an ideal choice for various surgical applications, promoting optimal bone healing and patient recovery.
Indications for Straight Locking Plate 2.0mm
The Straight Bridge Locking Plate 2.0mm is indicated for a variety of orthopedic and maxillofacial surgical procedures requiring enhanced stability and support, particularly in areas with significant bone load-bearing. Key indications include:
How a Straight Locking Plate 2.0mm Works
The Straight Locking Plate 2.0mm functions as a structural reinforcement for bone fractures or defects. It is secured to the bone using locking screws, which create a rigid and stable fixation. The increased thickness and width of the plate provide enhanced stability and load-bearing capacity compared to thinner plates. The straight design allows for versatile application in various bone configurations. Over time, the bone will naturally heal around the plate, creating a stable union.
FAQ
Q1: What is a Straight Locking Plate?
A Straight Locking Plate is a medical implant used in orthopedic and maxillofacial surgery, featuring a straight design with a locking mechanism for secure bone fixation.
Q2: What do the numbers “2.0mm T: 0.8mm” signify in the plate?
The “2.0mm” refers to the width of the plate, while “T: 0.8mm” indicates the thickness of the plate.
Q3: What is the significance of the locking mechanism?
The locking mechanism prevents screw backout, ensuring a secure and stable fixation of bone fragments.
Q4: What material is typically used for Straight Locking Plates?
Straight Locking Plates are commonly made from titanium due to its biocompatibility, strength, and resistance to corrosion.
Q5: What are the primary applications of a Straight Locking Plate?
Straight Locking Plates are used in orthopedic and maxillofacial surgery for complex fractures, bone reconstructions, and procedures requiring increased stability and support.
Q6: How is the Straight Locking Plate secured to the bone?
The plate is secured to the bone using locking screws, which create a rigid and stable connection.
Q7: What are the advantages of using a Straight Locking Plate compared to thinner plates?
Straight Locking Plates with increased thickness offer superior strength and stability, making them suitable for high-load-bearing areas and complex fractures.
Q8: Is the Straight Locking Plate a permanent implant?
In most cases, the Straight Locking Plate is designed as a permanent implant to provide long-term support and stability to the bone. Removal is typically considered only in specific circumstances.
Q9: What precautions should be taken during surgery?
Careful handling of the plate and screws is essential. Proper drilling technique and torque control are crucial for optimal placement and fixation.
Q10: What about post-operative care?
Standard post-operative care for orthopedic or maxillofacial surgery applies. Patients should follow their surgeon’s instructions for wound care, medication, and activity restrictions.
Oh yeah! I have to mention their payment options and discount offers, which are awesome! Those payment methods are as flexible as moving water and can be chosen freely according to our cash flow situation. And the frequent discounts, like a timely rain, have been moisturizing our financial statements time and again, and have had a rocket-like positive impact on our profits! With ZMD, I feel relaxed and at ease when it comes to purchasing!
Send us a message if you have any questions or request a quote. Our experts will give you a reply within 24 hours and help you select the right valve you want.
Book Now
If you are looking for professional orthopedic medical product solutions, don’t hesitate to contact us now!
We are an integrated manufacturer specializing in orthopedic medical industry, providing high quality and reliable orthopedic medical products to customers worldwide.
Copyright © 2024 ASK Project